Trace the fault sequence.
Which machine reported the fault first? Matching timestamps help your maintenance team reconstruct the sequence.
SPSTimeMaster synchronizes your PLC clocks automatically. Keep timestamps aligned without adjusting each clock individually.
Enlarge In everyday plant operations
For maintenance, production and quality teams, wherever timestamps need to match.
Which machine reported the fault first? Matching timestamps help your maintenance team reconstruct the sequence.
Align measurements and batch records from different controllers in time. Make analysis and quality checks easier.
PLC clocks synchronize automatically. There is no need to check and adjust each controller’s clock regularly.
Industrial companies trust [MB]




Inside the software
Set your schedule once. SPSTimeMaster regularly synchronizes the clocks of individual controllers or entire groups.
Enlarge See which PLC clocks have drifted and which controllers are unreachable. Know where to act.
Enlarge The current session’s history shows which PLC was synchronized, when it happened and whether it succeeded.
Enlarge Original software views with fictional example data.
Up to five connections: Basic. For more controllers: Pro with no connection limit.
€449
one-time per licence · net, excluding VAT
Up to 5 PLC connections
Synchronize individual machines or small installations centrally. For up to five PLCs on one PC.
Everything you need for up to 5 PLC connections.
€1,399
one-time per licence · net, excluding VAT
Unlimited PLC connections
Your whole factory hall from one PC. Add more PLCs without watching a connection limit.
Your choice from 6 PLC connections.
Updates are free in the first year. You can add the update plan for subsequent years when placing your order.
€9 net per month per licence, billed annually at €108. Starts in year two and renews automatically for one year at a time. Cancel at least one month before the end of the current update year.
Select your licence and quantity. If your purchasing department needs a written quotation first, request one without placing an order.
Trial version
Evaluate SPSTimeMaster for 30 days with your own controllers. Request the trial version by email and we will send you your personal download link. The software obtains its trial licence the first time it starts.
A non-binding enquiry by email. Opens your email application with a prepared message.
The people behind the software
We are [MB] Software und Systeme, based in Germany’s Westerwald region. We have been developing software since 2000. For help choosing, setting up or using your software, talk directly to our team.
Talk to our team →Explore the details
Find setup instructions, technical features and the requirements for your controllers here.
Synchronization can also be triggered when the deviation tolerance is exceeded. The PC clock provides the time reference. Recurring synchronization uses Windows Task Scheduler. No additional PLC program blocks are required.
Select discovered Siemens controllers and add them to your configuration together.
Enlarge Align the clocks of an entire line or plant area in one step. Groups save you from accessing each controller individually.
Enlarge Define the acceptable clock deviation and how often PLC clocks are checked. There is no need to compare the clocks manually at regular intervals.
Enlarge SPSTimeMaster keeps your Siemens S7 PLC clocks on a shared time reference. This is useful wherever you analyze timestamped PLC data or a PLC runs functions at specific times. It synchronizes PLC clocks with PC time on a schedule, when the deviation tolerance is exceeded, or manually.
Siemens S7-300 and S7-400 controllers with an Ethernet-capable CPU or communication processor, as well as unprotected S7-1200 and S7-1500 controllers. Unprotected means no password or UMAC access protection. CPUs with an unconfirmed TLS certificate are also outside the supported scope. The CPU must be reachable from the Windows PC. The software selects the appropriate communication method automatically.
No. The PLC program remains unchanged. SPSTimeMaster runs on a Windows PC and sets the PLC clock through S7 communication. Its time source is the PC clock, which should itself be synchronized with a reliable time source, for example via NTP.